





VapourTX Thermo
Highly Reflective, Low-Emissivity Foil AVCLReflective, high resistance vapour barrier enhancing thermal performance for internal walls, ceilings and floors.
- Premium Quality
- Cost Effective
- Technical Support
- Installation Guides
VapourTX® Thermo vapour control layer is a high-resistance vapour barrier specifically designed to reduce water vapour transfer through the building or structure when placed on the warm side of the insulation. VapourTX® Thermo is a reflective vapour control layer made from a nonwoven composite fabric incorporating a highly reflective, low-emissivity foil. This product offers exceptional performance as an air and vapour barrier. The reflective surface assists in enhancing overall thermal performance in the adjacent cavity. VapourTX® Thermo is ideal for various construction applications, including walls, ceilings, and floors.
Applications:
• To be installed on the internal / warm side of the insulation, with the Reflective face away from the insulation.
• It is used in a range of construction applications, including walls, ceilings, floors, pitched roofing and low-sloping metal roofing.
Features & Benefits:
• Forms a barrier against air leakage and water vapour transfer.
• The Reflective face is specifically designed to enhance the thermal performance of the structure to which it is applied.
• Fabric Weight 142g/m².
Colour | Silver |
---|---|
Mass Per Unit Area | 142g/m² |
Resistance to Fire | Class E |
Water Vapour Resistance - Sd Value | 150m |
Water Penetration Resistance | Class W1 |
Tensile Strength Longitudinal | 260 N/50mm |
Tensile Strength Transverse | 200 N/50mm |
Elongation Longitudinal | 59% |
Elongation Transverse | 70% |
Tear Resistance Longitudinal | 155N |
Tear Resistance Transverse | 155N |
Flexibility at Low Temp | No cracking at minus 40ºC |
Roll Area | 300 m² |
Application Area | Ceiling, Floors, Internal Wall, Loft Space |
Type of Build | Block, Steel Frame, Timber Frame |
Location | Internal |
Material | Aluminium |
Size | 3.0m x 100m |
Approx Coverage | 276m² |
Installation
Installation Guide:
- VapourTX Thermo is to be installed on the internal / warm side of the insulation, with the Reflective face away from the insulation.
- A minimum 19mm airspace should be maintained between the plasterboard and vapour control layer. This airspace should be utilised as a service void to reduce the number of penetrations to the VCL.
- Membrane should be fixed to studwork using staples, with min 19mm timber battens used to create service void.
- Laps to be min. 100mm and sealed with a proprietary silver tape.
- Penetrations and tears should be closed off using silver tape, with tears greater than 25mm to be covered by VCL patches with a min 100mm lap around the perimeter and well sealed with silver tape.
SKU
SKU: | Sizes: | Barcode: |
AR9087 | 270 mm x 100 m | |
AR9087A | 300 mm x 100 m | |
AR9087B | 150 mm x 50 m |