PHS Sd Variable Plus

Mesh Reinforced Airtight VCL Membrane - Variable Sd

Robust and flexible airtight membrane with a variable Sd value 0.4 – 35m. Excellent for flat roof builds and retrofits and suitable for air-injected insulation and insulation mats.

 

Features
  • Premium Quality
  • Cost Effective
  • Technical Support
  • Installation Guides

PHS Sd Variable Plus membrane is a triple layer fabric, high performance membrane, made from non-woven PP fabric. It is a robust airtight membrane with a variable Sd value. It’s reinforced mesh material is designed to create an airtight barrier within the home. With variable diffusion resistance, this membrane can adapt diffusion rates depending on the environment. The membrane creates an airtight layer that dynamically adjusts based on the humidity of the environment, preventing condensation build up and moisture damage. PHS Sd Variable Plus is highly recommended for flat roof builds.

Applications:
  • Interior installation to create an airtight envelope.
  • All construction types.
  • Especially suited to flat roofs and retrofits.
  • Ceilings, walls, floors and loft spaces.
Features & Benefits:
  • Robust  and flexible.
  • Highly tear resistant.
  • Variable diffusion resistance.
  • Moisture variable, sd value 0.4 – 35m.
  • Suitable for air-injected insulation and insulation mats.

 


 

Location

Internal

System

Airtight, Retrofit

Colour

Grey Graphics on White

Elongation Longitudinal

24%

Elongation Transverse

24%

Mass Per Unit Area

103g/m²

Material

Airtight Membrane

Resistance to Fire

Class E

Roll Area

75 m²

Roll Weight

7.7 kg

Water Vapour Resistance - Sd Value

0.4 – 35m, Variable

Size

1.5m x 50m

Tear Resistance Longitudinal

230 N

Tear Resistance Transverse

230 N

Tensile Strength Longitudinal

387 N/50mm

Tensile Strength Transverse

387 N/50mm

Thickness

0.27mm

Water Penetration Resistance

Class W1

Application Area

Ceiling, Internal Wall, Loft Space

Type of Build

Block, Steel Frame, Timber Frame

Airtight

<0.01 (m³/(m²*H*50Pa))

Approx Coverage

67 m²

μ=Value

48,148

Application

Installation Guide:
  1. Lay the membrane so that the printed side is facing the fitter.
  2. Lay the sheet parallel or at a right angle to the rafters with an overlap of at least 10cm.
  3. Ensure flush-mounted bay insulation, there should be no cavities between the bay insulation and membrane.
  4. The membrane is translucent making it easier to see markings, measurements and fixtures.
  5. Fit the membrane free of tension and avoid creases.
  6. Overlaps, component joints and penetrations must be made airtight with PHS sealing products including tapes and sealant.

 


 

SKU

SKU: Size:  Box Quantity:   Barcode:
AR9093A 1.5mx50m 1 05391536370923

Downloads

Technical Datasheet    Declaration of Performance    Installation Guide

 


 

Cost Effective
Fully Supported
Fast Application
All Construction Types
German Quality